  linkcom manufacturing co., ltd *,# =see notes below model specification ** * * * * (6)load regulation measured from 20% to full load. (7)line regulation measured from 100vac to 2 77vac. (8)preset accuracy measured at normal load, 120vac input. reference ver b *9 rohs safety: ul / tuv / cb / pse emc: ce / fcc comply with indoor/outdoor waterproof (ip 67) dimension (mm): l*w*h: 208.4mm*72mm*38.5mm module : lcch-100  120 features i/p-o/p, i/p-fg,o/p-fg :100m ohms / 500vdc / 25 / 70% rh 208.4mm*72mm*38.5mm (l*w*h) ce en55015 / fcc part 15 i/p-o/p 3.75kvac, o/p-grnd 0.5kvac, i/p-grnd 1.88kvac (9)100% production tested. (5)minimum load is not required for proper operat ion . notes (1)all parameters not specially mentioned are measured 230vac in put. (2)all specifications typical @25 , unless otherwise noted, at normal line and load. (3)ripple and noise measured directly at pins/ terminals at nom. load, 0.1uf bypass and 47uf electrolytic, pk-pk @20mhz bandwidth. (4)specified for free-air convection cooling. dimensions storage temperature over v, protection emi withstand voltage isolation resistance operating temp.*4 safety relative humidity preset accuracy (%) *8 25ms at full load 115vac/230vac hold up time ac input 100~277vac protection: ovp / otp / scp high operating ambient temp: -25 ~ +60 power factor:>0.98@115vac;>0.95@230vac;@full load 88% 96 w -40 to +80 10 to +90%, non-cond. temp. coefficient 0.03% / (0-50 , typ) -25 to +60 @full load cold start 65a @ 230vac ac current leakage current over temp. protection <0.45ma/264vac short circuit protection will restart automatically after the fault condition is removed short circuit protection 1.7a/115vac 0.65a/230vac shut down and latch off o/p voltage , re-power on t o recover output current(a) *5 inrush current (typ) dc output power pf>0.98@115vac ; pf>0.95@230vac at full load and ra ted output voltage input frequency 1 input voltage range 90-305vac, 127-431vdc, normal 100-277vac range:47-63hz, normal 50-60hz max. 12 model no. part no. power supply 208.4mm*72mm*38.5mm lcch-100  120 plcch1100  120 model name size o/p noise (p-p, mv) *3 setup,rise time(typ.) lcch-100  120 norm. 1 min. 8 load regulation (%) *6 1 ul 60950-1 / tuv en61347-2-13 / cb / pse efficiency(typ @full load) active power factor dc output voltage (v) line regulation (%) *7 2s,500ms at full load 115vac/230vac 8 250 www.linkcom.com.tw for more information, please contact with: sales@linkcom.co m.tw
linkcom manufacturing co., ltd ver b model no. part no. power supply 208.4mm*72mm*38.5mm lcch-100  120 plcch1100  120 model name size reference unit : mm dimensions derate www.linkcom.com.tw for more information, please contact with :sales @ linkcom.com.tw


▲Up To Search▲   

 
Price & Availability of LCCH-100X120

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X